Category Archives: Roof and Gutter Heating Cable

New Product on Our Website: Danfoss 088L9000 RX1200 Roof & Gutter Control

Item Code: DANFOSS088L9000
UPC/GTIN/Part #: 5703466241271
Description:  088L9000 RX1200 Roof & Gutter Control
 
Danfoss De-Icing Controller – 10.2 Amps – 120 Volts – 1225 Watts – On at 39.2F Off at 44.6F – Power & Heating Indicators – 4.9ft 16AWG Black Power Cord & grounded plug – 2.3ft Black Probe Lead – 9.84ft Black Moisture Sensor Wire – 6 Sensor Shingle Clips 
DANFOSS088L9000

 

http://www.morelectricheating.com/default.aspx?page=item+detail&itemcode=DANFOSS088L9000

New Product on Our Website: Raychem FrostGuard Heating Cable for Pipe Freeze Protection & Roof & Gutter De-Icing

 
       
Raychem FrostGuard preassembled self-regulating heating cables are designed for residential and commercial metal and plastic pipe freeze protection and roof and gutter deicing applications. 120 V FrostGuard cables are available in 6, 12, 18, 24, 36, 50, 75 and 100 foot lengths, and each comes assembled with a 6-ft power cord and 3-prong, grounded, lighted plug to show the system is on. 120 V FrostGuard
cables are ideal for smaller jobs such as roof and gutter deicing on porches and overhangs, as well as for pipe freeze protection on metal or plastic pipes up to 2-1/2 inches in diameter.

240 V FrostGuard cables are available in 6, 12, 18, and 24 foot lengths and each come assembled with a 6-ft power cord for terminating in a junction box. Due to their short lengths, 240 V FrostGuard cables are designed only for pipe freeze protection applications on pipes up to 2-1/2 inches in diameter.

Prevent frozen pipes and roof and gutter ice build-up with FrostGuard self-regulating heating cable. FrostGuard is easily installed on pipes for pipe freeze protection, or on Roof and Gutters for roof and gutter de-icing.

• 6 ft cold lead with lighted plug or hard-wired 240 V version
• Cable can be overlapped and won’t burn out
• Ideal for smaller jobs such as roof and gutter de-icing on porches and overhangs
• Can be used on roofs made from all types of materials, including shake, shingle, rubber, tar, wood, metal and plastic
• Available in 8 lengths in 120 V
• Ideal for metal and plastic pipes up to 2-1/2 inches in diameter

120V Version:
• Quick and easy installation, simply plug and go!
• Preassembled with a 6-ft power cord
• 3-prong, grounded, lighted plug to show the system has power
• No need for an electrician to wire the product to the power supply

240V Version:
• Preassembled with a 6-ft power cord for terminating in a junction box
• Ideal for metal and plastic pipes up to 2-1/2 inches in diameter
• Available in 4 lengths in 240 V
• Can be overlapped
• Can be connected to a thermostat for additional energy-efficient control

Raychem FrostGuard Sales Brochure (PDF)
FrostGuard Data Sheet (PDF)
FrostGuard 120 V Installation Instructions (PDF)

http://www.morelectricheating.com/products/MANUFACTURERS/RAYCHEM/FROSTGUARD.aspx

New Product On Our Website: Wrap-On Green Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers

Wrap-On Green Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers
Results Displayed: 1 – 29 of 29
 

Wrap-On Green Roof and Gutter Heating Cables

Each package contains one ready-to-install cable, shingle clips, cable spacers and complete installation instructions. You will also need a tape measure, marker, gloves, ladder and a weatherproof GFCI outlet with control switch.

Description


  • Prevents Water and Ice Damage by Providing a Clear Path for Melting Water
  • Keeps Roof Edges, Gutters and Downspouts Ice-Free
  • Adapts to Most Roof and Gutter Configurations
  • Easy to Install
  • Approved For Metal and Plastic Gutters
  • Complete with Clips and Spacers
  • USA UL and Canadian cUL Listed and CSA Certified
  • CSA Certified and UL Listed to Canadian safety standards
  • Two-Year Limited Warranty

Roof & Gutter Cables prevent water damage caused by snow and ice buildup. Once again, working in conjunction with Underwriters Laboratories (UL), Wrap-On was granted the industry’s first listing for the newly created category, “Roof and Gutter De-icing Cable for Metal or Plastic/Vinyl Gutters and Downspouts.”

The Roof and Gutter cables work in conjunction with natural sunlight and a building’s own heat dissipation. When natural thawing occurs, the cables create a channel that allows water to flow off the roof and through gutters and downspouts. Easy to operate, they simply plug in for years of trouble-free operation.

The Wrap-On® Company has been manufacturing electric pipe heating cables, roof & gutter cables and a variety of other winterization products for more than fifty seven years. Wrap-On introduced the first pipe heating cable to the market in the early 1940’s. Other products such as roof & gutter cables and pipe insulation soon followed. In the years since, we have continually improved and updated our products to meet the changing needs of our customers.

Wrap-On Roof and Gutter Cables are the ideal preventative maintenance for snow and ice buildup. They create channels on the roof, in the gutter and in the downspout that allow melting ice and snow to flow freely, eliminating ice dams and Greenucing icicle formation. They can be used safely on all metal, plastic and vinyl gutters and downspouts and are UL listed and CSA certified. Packaging includes detailed instructions and all necessary hardware.

Even in below freezing weather, snow on the roof will often thaw because of heat from the sun and heat loss from the house through the roof. As this melted snow reaches the roof overhang it refreezes. Here there is no heat loss so the roof surface is much colder. As this melted snow refreezes again and again on the roof overhang, an ice dam is formed. Soon water backs up under shingles, and leaks into the house. It’s not those big icicles that do the real damage, it’s the ice you don’t see that backs up in gutters and under shingles. When the ice melts it can really do a number on repair costs. Roof de-icing cable prevents this water and ice damage by providing a clear path for melting water to flow off the roof. It keeps roof edges, gutters and downspouts ice-free. Versatile design adapts to most roof and gutter configurations. This product is intended for the sole use of preventing ice dams from forming on inclined roofs with tab shingles, in gutters and downspouts. This roof de-icing cable is not intended for use as a snow melting system to clear roof of ice and snow.

Cable Installation Patterns (One cable may cover both roof and gutter areas, or separate cables can be used.)

This pre-assembled cable has been designed for the sole purpose of preventing the formation of ice dams on pitched roofs with non-combustible tab shingles and in metal or plastic gutters and downspouts. It provides drainage channels so that as natural thawing occurs, water has a path to flow off the roof and through the gutters and downspouts. This cable is not for use on a flat roof nor is it intended to clear the roof of snow and ice.

Item Code Description
WRAPON14085
14084 80Ft 400W 120V Green Heating Cable
Wrap-On Co., Inc. Kit of Green Roof & Gutter De-Icing Heat Trace Cable – 80 Feet Long – 400 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 2 14500)
WRAPON14105
14104 100Ft 500W 120V Green Heat Cable
Wrap-On Co., Inc. Kit of Green Roof & Gutter De-Icing Heat Trace Cable – 100 Feet Long – 500 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 3 14500)
WRAPON14125
14125 120Ft 600W 120V Green Heat Cable
Wrap-On Co., Inc. Kit of Green Roof & Gutter De-Icing Heat Trace Cable – 120 Feet Long – 600 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 3 14500)

New Product On Our Website: Wrap-On Brown Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers

Wrap-On Brown Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers
 

Wrap-On Brown Roof and Gutter Heating Cables

Each package contains one ready-to-install cable, shingle clips, cable spacers and complete installation instructions. You will also need a tape measure, marker, gloves, ladder and a weatherproof GFCI outlet with control switch.

Description


  • Prevents Water and Ice Damage by Providing a Clear Path for Melting Water
  • Keeps Roof Edges, Gutters and Downspouts Ice-Free
  • Adapts to Most Roof and Gutter Configurations
  • Easy to Install
  • Approved For Metal and Plastic Gutters
  • Complete with Clips and Spacers
  • USA UL and Canadian cUL Listed and CSA Certified
  • CSA Certified and UL Listed to Canadian safety standards
  • Two-Year Limited Warranty

Roof & Gutter Cables prevent water damage caused by snow and ice buildup. Once again, working in conjunction with Underwriters Laboratories (UL), Wrap-On was granted the industry’s first listing for the newly created category, “Roof and Gutter De-icing Cable for Metal or Plastic/Vinyl Gutters and Downspouts.”

The Roof and Gutter cables work in conjunction with natural sunlight and a building’s own heat dissipation. When natural thawing occurs, the cables create a channel that allows water to flow off the roof and through gutters and downspouts. Easy to operate, they simply plug in for years of trouble-free operation.

The Wrap-On® Company has been manufacturing electric pipe heating cables, roof & gutter cables and a variety of other winterization products for more than fifty seven years. Wrap-On introduced the first pipe heating cable to the market in the early 1940’s. Other products such as roof & gutter cables and pipe insulation soon followed. In the years since, we have continually improved and updated our products to meet the changing needs of our customers.

Wrap-On Roof and Gutter Cables are the ideal preventative maintenance for snow and ice buildup. They create channels on the roof, in the gutter and in the downspout that allow melting ice and snow to flow freely, eliminating ice dams and reducing icicle formation. They can be used safely on all metal, plastic and vinyl gutters and downspouts and are UL listed and CSA certified. Packaging includes detailed instructions and all necessary hardware.

Even in below freezing weather, snow on the roof will often thaw because of heat from the sun and heat loss from the house through the roof. As this melted snow reaches the roof overhang it refreezes. Here there is no heat loss so the roof surface is much colder. As this melted snow refreezes again and again on the roof overhang, an ice dam is formed. Soon water backs up under shingles, and leaks into the house. It’s not those big icicles that do the real damage, it’s the ice you don’t see that backs up in gutters and under shingles. When the ice melts it can really do a number on repair costs. Roof de-icing cable prevents this water and ice damage by providing a clear path for melting water to flow off the roof. It keeps roof edges, gutters and downspouts ice-free. Versatile design adapts to most roof and gutter configurations. This product is intended for the sole use of preventing ice dams from forming on inclined roofs with tab shingles, in gutters and downspouts. This roof de-icing cable is not intended for use as a snow melting system to clear roof of ice and snow.

Cable Installation Patterns (One cable may cover both roof and gutter areas, or separate cables can be used.)

This pre-assembled cable has been designed for the sole purpose of preventing the formation of ice dams on pitched roofs with non-combustible tab shingles and in metal or plastic gutters and downspouts. It provides drainage channels so that as natural thawing occurs, water has a path to flow off the roof and through the gutters and downspouts. This cable is not for use on a flat roof nor is it intended to clear the roof of snow and ice. 

Item Code Description
WRAPON14082
14082 80Ft 400W 120V Brown Heating Cable
Wrap-On Co., Inc. Kit of Brown Roof & Gutter De-Icing Heat Trace Cable – 80 Feet Long – 400 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 2 14500)
WRAPON14102
14102 100Ft 500W 120V Brown Heat Cable
Wrap-On Co., Inc. Kit of Brown Roof & Gutter De-Icing Heat Trace Cable – 100 Feet Long – 500 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 3 14500)
WRAPON14122
14122 120Ft 600W 120V Brown Heat Cable
Wrap-On Co., Inc. Kit of Brown Roof & Gutter De-Icing Heat Trace Cable – 120 Feet Long – 600 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 3 14500)

New Product On Our Website: Wrap-On Red Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers

Wrap-On Red Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers
Results Displayed: 1 – 29 of 29
 

Wrap-On Red Roof and Gutter Heating Cables

Each package contains one ready-to-install cable, shingle clips, cable spacers and complete installation instructions. You will also need a tape measure, marker, gloves, ladder and a weatherproof GFCI outlet with control switch.

Description


  • Prevents Water and Ice Damage by Providing a Clear Path for Melting Water
  • Keeps Roof Edges, Gutters and Downspouts Ice-Free
  • Adapts to Most Roof and Gutter Configurations
  • Easy to Install
  • Approved For Metal and Plastic Gutters
  • Complete with Clips and Spacers
  • USA UL and Canadian cUL Listed and CSA Certified
  • CSA Certified and UL Listed to Canadian safety standards
  • Two-Year Limited Warranty


Roof & Gutter Cables prevent water damage caused by snow and ice buildup. Once again, working in conjunction with Underwriters Laboratories (UL), Wrap-On was granted the industry’s first listing for the newly created category, “Roof and Gutter De-icing Cable for Metal or Plastic/Vinyl Gutters and Downspouts.”

The Roof and Gutter cables work in conjunction with natural sunlight and a building’s own heat dissipation. When natural thawing occurs, the cables create a channel that allows water to flow off the roof and through gutters and downspouts. Easy to operate, they simply plug in for years of trouble-free operation.

The Wrap-On® Company has been manufacturing electric pipe heating cables, roof & gutter cables and a variety of other winterization products for more than fifty seven years. Wrap-On introduced the first pipe heating cable to the market in the early 1940’s. Other products such as roof & gutter cables and pipe insulation soon followed. In the years since, we have continually improved and updated our products to meet the changing needs of our customers.

Wrap-On Roof and Gutter Cables are the ideal preventative maintenance for snow and ice buildup. They create channels on the roof, in the gutter and in the downspout that allow melting ice and snow to flow freely, eliminating ice dams and reducing icicle formation. They can be used safely on all metal, plastic and vinyl gutters and downspouts and are UL listed and CSA certified. Packaging includes detailed instructions and all necessary hardware.

Even in below freezing weather, snow on the roof will often thaw because of heat from the sun and heat loss from the house through the roof. As this melted snow reaches the roof overhang it refreezes. Here there is no heat loss so the roof surface is much colder. As this melted snow refreezes again and again on the roof overhang, an ice dam is formed. Soon water backs up under shingles, and leaks into the house. It’s not those big icicles that do the real damage, it’s the ice you don’t see that backs up in gutters and under shingles. When the ice melts it can really do a number on repair costs. Roof de-icing cable prevents this water and ice damage by providing a clear path for melting water to flow off the roof. It keeps roof edges, gutters and downspouts ice-free. Versatile design adapts to most roof and gutter configurations. This product is intended for the sole use of preventing ice dams from forming on inclined roofs with tab shingles, in gutters and downspouts. This roof de-icing cable is not intended for use as a snow melting system to clear roof of ice and snow.

Cable Installation Patterns (One cable may cover both roof and gutter areas, or separate cables can be used.)

This pre-assembled cable has been designed for the sole purpose of preventing the formation of ice dams on pitched roofs with non-combustible tab shingles and in metal or plastic gutters and downspouts. It provides drainage channels so that as natural thawing occurs, water has a path to flow off the roof and through the gutters and downspouts. This cable is not for use on a flat roof nor is it intended to clear the roof of snow and ice. 

Item Code Description
WRAPON14083
14083 80Ft 400W 120V Red Heating Cable
Wrap-On Co., Inc. Kit of Red Roof & Gutter De-Icing Heat Trace Cable – 80 Feet Long – 400 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 2 14500)
WRAPON14103
14103 100Ft 500W 120V Red Heating Cable
Wrap-On Co., Inc. Kit of Red Roof & Gutter De-Icing Heat Trace Cable – 100 Feet Long – 500 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 3 14500)
WRAPON14123
14123 120Ft 600W 120V Red Heat Cable
Wrap-On Co., Inc. Kit of Red Roof & Gutter De-Icing Heat Trace Cable – 120 Feet Long – 600 Watt – Residential Grade – 120 Volt – 5 Watts per Foot with 6 Foot Power Cord & Plug & Roof Clips & Cable Spacers (Includes 3 14500)

Wrap-On Custom Colored Roof and Gutter Heating Cables

Wrap-on has introduced their roof and gutter heating cable in custom colors. They have the capability to make them in almost any color. Please call us if you have a need for a large quantity of cables that will be installed on matching roofs, such as an apartment complex, etc. We will get you a quote on the cables and setup charge if any. 3 of the new typical colors are in the pictures below (red, green and brown). Their black color was actually their first new color and it is a stocked item. It was introduced last year at http://www.morelectricheating.com/products/MANUFACTURERS/WRAP-ON/WRAPON%20BLACK.aspx


Wrap-On Red Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits:
redrgchttp://www.morelectricheating.com/products/MANUFACTURERS/WRAP-ON/WRAPON%20RED.aspx


Wrap-On Green Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits:
greenrgc
http://www.morelectricheating.com/products/MANUFACTURERS/WRAP-ON/WRAPON%20GREEN.aspx


Wrap-On Brown Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits:
brownrgchttp://www.morelectricheating.com/products/MANUFACTURERS/WRAP-ON/WRAPON%20BROWN.aspx

New Product on Our Website: Calorique Perfectly Clear Roof Deicing 120V or 240V modular panels. Conceal under existing asphalt roof shingles or install with new shingles. 3’, 4’, 5’, 10’, 20’ & 25’ lengths

Calorique Perfectly Clear Roof Deicing 120V or 240V modular panels. Conceal under existing asphalt roof shingles or install with new shingles. 3’, 4’, 5’, 10’, 20’ & 25’ lengths
Results Displayed: 1 – 39 of 39
Roof Deicing Designed for Asphalt Roof Shingles

Calorique’s PerfectlyClear Roof Deicing is the most advanced ice dam prevention solution on the market today. Our unique heating panels feature a thin profile. When installed, they are completely concealed underneath the asphalt shingle. The roof deicing heating panels are available in various standard lengths to provide for any configuration.

The modular design allows the roofing contractor to easily plug heating panels together positioning them in and around problem areas. The panels are easily installed as a “Retro Fit” under existing shingles, or at New Shingle Installation. Our roof deicing products provide ice dam prevention for valleys too.

Installation is easy – By removing the underside release liner and firmly pressing down, the heating panel locks securely in place. Removing the top release liner strip, seals the panel to the next course of shingles.

Simple, fast and easy ! PerfectlyClear Roof Deicing combined with PerfectlyClear Gutter and Downspout Heat Ribbons plus an optional automated controller/snow sensor, protects buildings against dangerous ice build-up – safely and efficiently.

Features:

– Prevents Ice Dams from Forming
– For New or Existing Asphalt Roofs
– Retro Fit installation is completely concealed
– No Nailing Required
– ETL Intertek Listed
– 15 year Limited Warranty
– Certified to withstand 110 MPH Winds
– Completely Waterproof
– Easy to Install
– 120V and 240V
– Less than 10 Watts per linear foot
– Maintenance Free

 http://www.morelectricheating.com/products/MANUFACTURERS/CALORIQUE/PERFECTLYCLEAR.aspx

New Product – Danfoss RX-C Roof Clip (50pcs in Bag)

Danfoss has introduced a roof clip that is the same as the other manufacturers:

http://www.morelectricheating.com/products/MANUFACTURERS/DANFOSS/RX-C%20ROOF%20CLIP.aspx

They have a real nice installation guide it is linked below. It says DO NOT NAIL OR SCREW TO YOUR ROOF! They say to only use adhesive and to consult roofing supplier for recommended adhesives and specifically mention  asphalt shingles.

roofwithout

http://www.morelectricheating.com/contentonly.aspx?file=product_pdf_info/RX-C_Roof_Clips_Data_Sheet_VDLWA122_3_16.pdf

088L3001 RX-C 50 Roof Clips

(50pcs in Bag)
UPC: 5703466239285
The Danfoss RX-C Roof Clips are suitable for use with the RX-C Self Regulating Cables. The clips are designed to secure the cables to asphalt shingles, metal seam roofs, and gutters.

Tools Required:
• pliers
• caulking gun
• adhesive (see below)

• Shingles must be clean and dry
• Note adhesive application temperature limits
• Allow proper cure time for adhesive (typically 24 hours)
• Not recommended for rubber/membrane roof
• Do not use screw/nail with clip
• Consult roofing supplier for recommended adhesives

Recommended Adhesives:
See roofing supply distributors for recommendations

1. Apply Adhesive:
• Apply 0.2 oz. of adhesive to back of clip.
• (Please note required application temperatures when applying glue.)

2. Press Clip to Roof Surface:
• Lift shingle & orient clip.
• Press down (ensure adhesive flows through holes).
• Do not trim back adhesive beads.
• Press shingle down.

3. Install Cables/Close Clamps
• Allow proper cure time (typically 24 hours- refer to adhesive.)
• Install RX-C de-icing cable.
• Use pliers to close clamps (ensuring not to damage cable).

Warning
• Roof clips must be installed properly to ensure proper operation and to prevent the risk of electrical hazard or fire. Follow all design, installation, assembly, and test instructions carefully.
• Arcing may not be stopped by conventional circuit protection.
• Do not use clip for installation on slate or tile roofs as damage may occur to roof material. Consult roofing manufacturer for components approved for use on specific roof material.
• De-energize all power circuits before installation or servicing.
• Keep ends of heating devices and kit components dry before and during installation.
• While using pliers to close clamps on heating cable, heating cable should not be crushed or altered structurally in any way.
• The cable should not be twisted during installation.
• Heating cable should not be embedded in the thermal insulation.

Constant Wattage Roof and Gutter De-Icing Cable

Many people are looking for the most inexpensive and easiest to install heating cable for their roof which is what is called constant wattage roof cable. It is a smaller cable that can be use with shingle piercing roof clips as opposed to self-regulating cable which requires clips that are glued and/or nailed and screwed down. There are six manufacturers of constant wattage cable and we sell four of them. EasyHeat makes ADKS,  Wrap-on makes their grey and black cables, King Electric makes their CWR and Danfoss makes their RX-C cables. There are also a couple of other brands we do not sell called Frost King and M-D Building Products which are similar.

EasyHeat ADKS Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with roof clips & spacers (12)
Wrap-On Black Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers (16)
DanFoss RX Series Roof & Gutter Electric Constant Watt De-Icing Heating Cable Kits with Shingle Clips & Spacers (17)
Wrap-On Grey Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers (15)
King Electric CWR Series 120 Volt Constant Wattage Roof & Gutter De-icing Cable prevents ice dams. 20 – 240 Foot Lengths. 5 watts/sq. ft. (12)

http://www.morelectricheating.com/products/CONSTANT%20ROOF.aspx

EasyHeat ADKS Substitutes (Constant Wattage Roof & Gutter Deicing Cable)

Mor Electric Heating is one the largest distributors in the USA of Roof & Gutter Heating Cable. We spend alot of time procuring constant wattage cable because it is one of our highest volume products. The Danfoss and Wrap-On brands have long been a fallback as EasyHeat ADKS gets hard to acquire by late Fall (currently it is the 80, 160, 200 and 240 foot lengths). Nearly every year the high demand causes EasyHeat to run out and we have recorded lead times as long as 13 weeks 5 years ago and again this year. The problem with the Danfoss brand has been their slightly different lengths (except for a few sizes such as the 80 foot length) and with the Wrap-On brand it has been the  grey color instead of black.

Now for the first season we have an exact substitute in King Electric and Wrap-On has released a black color, however Wrap-On (and Danfoss) come with a different shingle clip that has a larger tooth that pierces completely through the shingle, see below:

http://www.morelectricheating.com/default.aspx?page=item+detail&itemcode=WRAPON14500

Both brands are the same color, length and price and as good or better quality.

ADKS-400 (80 Foot):

The substitute for the ADKS-400 in the Wrap-on brand is here:

http://www.morelectricheating.com/products/ROOF%20AND%20GUTTER%20DEICING/default.aspx?page=item%20detail&itemcode=WRAPON14081

and the King Electric brand is here:

http://www.morelectricheating.com/products/ROOF%20AND%20GUTTER%20DEICING/default.aspx?page=item%20detail&itemcode=KINGELECTRIC48704

and the Danfoss brand is here:

http://www.morelectricheating.com/default.aspx?page=item%20detail&itemcode=DANFOSS088L3503

ADKS-800 (160 Foot):

The substitute for the ADKS-800 in the Wrap-on brand is here:

http://www.morelectricheating.com/products/ROOF%20AND%20GUTTER%20DEICING/default.aspx?page=item%20detail&itemcode=WRAPON14161

and the King Electric brand is here:

http://www.morelectricheating.com/products/ROOF%20AND%20GUTTER%20DEICING/default.aspx?page=item%20detail&itemcode=KINGELECTRIC48707

ADKS-1000 (200 Foot):

The substitute for the ADKS-1000 in the Wrap-on brand is here:

http://www.morelectricheating.com/products/ROOF%20AND%20GUTTER%20DEICING/default.aspx?page=item%20detail&itemcode=WRAPON14201

and the King Electric brand is here:

http://www.morelectricheating.com/products/ROOF%20AND%20GUTTER%20DEICING/default.aspx?page=item%20detail&itemcode=KINGELECTRIC48708

ADKS-1200 (240 Foot):

The substitute for the ADKS-1200 in the Wrap-on brand is here:

http://www.morelectricheating.com/products/ROOF%20AND%20GUTTER%20DEICING/default.aspx?page=item%20detail&itemcode=WRAPON14241

and the King Electric brand is here:

http://www.morelectricheating.com/products/ROOF%20AND%20GUTTER%20DEICING/default.aspx?page=item%20detail&itemcode=KINGELECTRIC48709

 

New Product: EasyHeat T4XA Ambient-Sensing Thermostat 22A

http://www.morelectricheating.com/products/MANUFACTURERS/EASY%20HEAT/T4XA.aspx

EasyHeat T4XA Nema 4X thermostat – 22 Amp – 15-140 Deg F – controls electric heating cables for freeze protection pipe tracing or roof & gutter de-icing
EasyHeat T4XA Ambient Sensing Adjustable Temperature NEMA 4X – 22A- 15-140 Deg F – ambient sensing. T4XA Thermostat controls electric heating cables for freeze protection pipe tracing or roof & gutter de-icing. The T4XA thermostat is suitable for indoor/outdoor locations having hostile, non-hazardous environments and controls a variety of electric heating cables for freeze-protection pipe tracing or roof and gutter de-icing.

Enclosure
NEMA 4X Polyurethane-coated Die Cast Aluminum
(max. 0.6% copper)

Temperature Range
Adjustable
15°F to 140°F (-9°C to 60°C)

Calibration Accuracy
1.3°F (0.7°C)

capillary
Stainless Steel

Max. Exposure Temp.
160°F (71°C)

Electrical
SPDT Switch
22 amp Resistive, 125/250/480 VAC
10 – 14 AWG Terminals
“NC” Contact Closes on Falling Temperature

Approvals
UL
CSA

This control appears to be the same as the Raychem version:

http://www.morelectricheating.com/default.aspx?page=item%20detail&itemcode=RAYCHEM10141

125 and 150 footers from BriskHeat

King Electric was the first to market with self-regulating heating cable kits (Freeze Protection Cable for Water Pipes and Roofs) longer than 100 feet.  They were an instant success, selling out very quickly.

Last week Briskheat introduced the same:

http://www.morelectricheating.com/default.aspx?page=item+detail&itemcode=BRISKHEAT10067

http://www.morelectricheating.com/default.aspx?page=item+detail&itemcode=BRISKHEAT10068

 

Briskheat SpeedTrace 5 watts/ft. Pre-Assembled Self-Regulating Pipe Heating Cable or Roof & Gutter Deicing
Features:

•Ideal for freeze protection and thawing: metal or plastic pipes and valves
•Indoor or outdoor use
•Suitable for temperatures down to: -40°F (-40°C)
•Easy-to-install: pre-assembled with power cord and plug
•Safe to overlap and insulate
•Automatically adjusts heat output based on surface and ambient temperature
•No temperature controller is required

Specifications:
•Supply voltage: 110-120VAC
•5 watts/ft (16 watts/m) at 50°F (10°C)
•8 watts/ft (26 watts/m) at 32°F (0°C)
•Maximum exposure temperature: 150°F (65°C)
•Moisture and flame resistant thermoplastic elastomer outer jacket 16 AWG bus wires
•Pre-terminated 30” (76cm) long power cord with standard 3-prong (NEMA-5-15) plug

Wrap-on has begun manufacturing 160 and 240 black roof cables (Roof & Gutter De-Icing Electric Constant Watt Heating Cable Kits with shingle clips & spacers)

ADKS-800 and ADKS-1200 have been particularly hard to get this season. Wrap-on has stepped up to the plate and is able to make hundreds per week of a direct size substitute:

160 Foot:
http://www.morelectricheating.com/default.aspx?page=item+detail&itemcode=WRAPON14161

240 Foot:
http://www.morelectricheating.com/default.aspx?page=item+detail&itemcode=WRAPON14241

BriskHeat HOT SHOTS – #008 Roof & Gutter De-Icing Kit Success!

HOT SHOT #008 BriskHeat Roof & Gutter De-Icing Kits!

 

Winter is upon us and many businesses and homes will be facing challenges relating to snow and ice on their premises.  A commonly overlooked and misunderstood winter hazard is the formation of ICE DAMS on rooftops.  After reading this, we’re sure those innocent looking icicles won’t be so innocent anymore.

 

What is an Ice Dam?

Ice Dams form due to the inherent temperature differences between heated spaces and roof overhangs. Naturally, some heat loss occurs through a homes attic. As it passes through the attic space it warms the roof [1].  Snow-melt then runs under the insulating blanket of snow, until it reaches a cold section of the roof and freezes to form an ice dam [2].  Snow that melts later cannot drain properly and is trapped on the roof [3]. Standing water can then enter a home or business causing significant property damage [4].

 

 

 

Icicles on overhangs and gutters are natures way of hinting that there might be a problem on the roof.  When icicles or even an ice dam breaks free, it can cause significant harm to customers and employees, vehicles, landscaping, etc., furthermore, dripping ice causes slippery walkways leading to possible injuries.

 

Weight of the ice can even pull gutters away from the roof, exposing the wood fascia to even more damage and dripping water hazards.

 

 

 

 

 

 

 

 

 

BriskHeat Partners across the nation are turning these hazards into opportunities to sell BriskHeat’s SpeedTrace Roof & Gutter De-Icing Kits.  These kits are designed to prevent ice and snow build-up on rooftops by using an electric self-regulating heating cable system. The heating cable melts away excessive snow and ice from the roof, gutters, and downspouts to ensure safe and proper draining.

 

The kits are easy-to-install and come complete with a plug-in ready self-regulating heating cable (with 3-prong plug), aluminum roof clips, and UV resistant cable ties for installation.  Available in your choice of 50, 75, 100, 125, and 150ft lengths to fit your needs.

 

SpeedTrace self-regulating heating cables are heavy duty professional grade heating cables. They out perform the less expensive big-box store products.  Safe for commercial and residential applications.

 

It’s not too late to introduce this product to maintenance crews and other customers.  Show them how they can protect their homes, businesses, and the people around them with a SpeedTrace Roof & Gutter De-Icing system.

http://www.morelectricheating.com/products/MANUFACTURERS/BRISKHEAT.aspx

Self-Regulating Roof Cable with a Plug and Cord Set

We continue to add vendors for commercial grade Roof and Gutter Heating Cable (Self-Regulating Roof Cable with a Plug and Cord Set) because it can be so difficult to get PSR in October and November and volumes are so high.

Here is a comparison chart:

Self-Regulating Heating Cable with a Plug and Cord Set